Part Number Hot Search : 
4148SE 3477M000 BT5401 C78L45BD G4PC50K 24298 85631 16000
Product Description
Full Text Search
 

To Download 70V9089DS82476 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 HIGH-SPEED 3.3V 64K x 8 SYNCHRONOUS DUAL-PORT STATIC RAM
Features:
x x
IDT70V9089S/L
x
x
x
True Dual-Ported memory cells which allow simultaneous access of the same memory location High-speed clock to data access - Commercial: 9/12/15ns (max.) Low-power operation - IDT70V9089S Active: 429mW (typ.) Standby: 3.3mW (typ.) - IDT70V9089L Active: 429mW (typ.) Standby: 660mW (typ.) Flow-Through or Pipelined output mode on either port via the FT/PIPE pin Counter enable and reset features
x
x
x x
x
Dual chip enables allow for depth expansion without additional logic Full synchronous operation on both ports - 4ns setup to clock and 1ns hold on all control, data, and address inputs - Data input, address, and control registers - Fast 9ns clock to data out in the Pipelined output mode - Self-timed write allows fast cycle time - 15ns cycle time, 66MHz operation in the Pipelined output mode LVTTL- compatible, single 3.3V (0.3V) power supply Industrial temperature range (-40C to +85C) is available for selected speeds Available in a 100 pin Thin Quad Flatpack (TQFP) package
Functional Block Diagram
R/WL OEL CE0L CE1L R/WR OER CE0R CE1R
1 0 0/1
1 0 0/1
FT/PIPEL
0/1
1
0
0
1
0/1
FT/PIPER
I/O0L - I/O7L I/O Control I/O Control
I/O0R - I/O7R
A15L A0L CLKL ADSL CNTENL CNTRSTL Counter/ Address Reg. MEMORY ARRAY Counter/ Address Reg.
A15R A0R CLKR ADSR CNTENR CNTRSTR
3750 drw 01
JANUARY 2001
1
(c)2000 Integrated Device Technology, Inc. DSC 3750/6
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Description:
The IDT70V9089 is a high-speed 64K x 8 bit synNchronous DualPort RAM. The memory array utilizes Dual-Port memory cells to allow simultaneous access of any address from both ports. Registers on control, data, and address inputs provide minimal setup and hold times. The timing latitude provided by this approach allows systems to be designed with very short cycle times. With an input data register, the IDT70V9089 has been optimized for applications having unidirectional or bidirectional data flow in bursts. An automatic power down feature, controlled by CE0 and CE1, permits the on-chip circuitry of each port to enter a very low standby power mode. Fabricated using IDT's CMOS high-performance technology, these devices typically operate on only 429mW of power.
Pin Configurations(1,2,3)
Index
NC NC A7L A8L A9L A10L A11L A12L A13L A14L A15L NC VCC NC NC NC NC CE0L CE1L CNTRSTL R/WL OEL FT/PIPEL NC NC
100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 3 73 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 72 71 70 69 68 67
NC NC A6L A5L A4L A3L A2L A1L A0L CNTENL CLKL ADSL GND ADSR CLKR CNTENR A0R A1R A2R A3R A4R A5R A6R NC NC
IDT70V9089PF PN100-1(4) 100-PIN TQFP TOP VIEW(5)
66 65 64 63 62 61 60 59 58 57 56 55 54 53 52
51 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
NC NC A7R A8R A9R A10R A11R A12R A13R A14R A15R NC GND NC NC NC NC CE0R CE1R CNTRSTR R/WR OER FT/PIPER GND NC
3750 drw 02
,
NOTES: 1. All Vcc pins must be connected to power supply. 2. All GND pins must be connected to ground. 3. Package body is approximately 14mm x 14mm x 1.4mm. 4. This package code is used to reference the package diagram. 5. This text does not indicate orientation of the actual part-marking.
GND NC I/O7L I/O6L I/O5L I/O4L I/O3L I/O2L GND I/OIL I/O0L VCC GND I/O0R I/O1R I/O2R VCC I/O3R I/O4R I/O5R I/O6R I/O7R NC NC NC
2 6.42
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Pin Names
Left Port CE0L, CE1L R/WL OEL A0L - A15L I/O0L - I/O7L CLKL ADSL CNTENL CNTRSTL FT/PIPEL Right Port CE0R, CE1R R/WR OER A0R - A15R I/O0R - I/O7R CLKR ADSR CNTENR CNTRSTR FT/PIPER VCC GND Names Chip Enables Read/Write Enable Output Enable Address Data Input/Output Clock Address Strobe Counter Enable Counter Reset Flow-Through/Pipeline Power Ground
3750 tbl 01
Truth Table IRead/Write and Enable Control(1,2,3)
OE
X X X L H CLK X
CE0
H X L L L
CE1
X L H H H
R/W X X L H X
I/O0-7 High-Z High-Z DIN DOUT High-Z
Mode Deselected Deselected Write Read Outputs Disabled
3750 tbl 02
NOTES: 1. "H" = VIH, "L" = VIL, "X" = Don't Care. 2. ADS, CNTEN, CNTRST = X. 3. OE is an asynchronous input signal.
Truth Table IIAddress Counter Control(1,2)
Address X An An X Previous Address X X Ap Ap Addr Used 0 An Ap Ap + 1 CLK(6) ADS X L
(4)
CNTEN X X H L
(5)
CNTRST L
(4)
I/O(3) DI/O(0) DI/O (n) DI/O(p) DI/O(p+1) Counter Reset to Address 0 External Address Used
MODE
H H H
H H
External Address Blocked--Counter disabled (Ap reused) Counter Enabled--Internal Address generation
3750 tbl 03
NOTES: 1. "H" = VIH, "L" = VIL, "X" = Don't Care. 2. CE0 and OE = VIL; CE1 and R/W = VIH. 3. Outputs configured in Flow-Through Output mode; if outputs are in Pipelined mode the data out will be delayed by one cycle. 4. ADS is independent of all other signals including CE0 and CE1. 5. The address counter advances if CNTEN = VIL on the rising edge of CLK, regardless of all other signals including CE0 and CE1.
6.42 3
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Recommended Operating Temperature and Supply Voltage(1,2)
Grade Commercial Industrial Ambient Temperature 0OC to +70OC -40OC to +85OC GND 0V 0V Vcc 3.3V + 0.3V 3.3V + 0.3V
3750 tbl 04
Recommended DC Operating Conditions
Symbol VCC GND VIH VIL Parameter Supply Voltage Ground Input High Voltage Input Low Voltage Min. 3.0 0 2.2 -0.3(2) Typ. 3.3 0
____
Max. 3.6 0 VCC + 0.3V(1) 0.8
Unit V V V V
3750 tbl 05
NOTES: 1. This is the parameter TA. This is the "instant on" case temperature. 2. Industrial temperature: for specific speeds, packages and powers contact your sales office.
____
NOTES: 1. VTERM must not exceed VCC +0.3V. 2. VIL > -1.5V for pulse width less than 10ns.
Absolute Maximum Ratings(1)
Symbol VTERM(2) Rating Terminal Voltage with Respect to GND Temperature Under Bias Storage Temperature DC Output Current Commercial & Industrial -0.5 to +4.6 Unit V
Capacitance (TA = +25C, f = 1.0MHz)
Symbol CIN COUT
(3)
Parameter(1) Input Capacitance Output Capacitance
Conditions(2) VIN = 3dV VOUT = 3dV
Max. 9 10
Unit pF pF
3750 tbl 07
TBIAS TSTG IOUT
-55 to +125 -65 to +150 50
o
C C
o
NOTES: 1. These parameters are determined by device characterization, but are not production tested. 2. 3dV references the interpolated capacitance when the input and output switch from 0V to 3V or from 3V to 0V. 3. COUT also references CI/O.
mA
3750 tbl 06
NOTES: 1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 2. VTERM must not exceed VCC +0.3V for more than 25% of the cycle time or 10ns maximum, and is limited to < 20mA for the period of VTERM > Vcc + 0.3V.
4 6.42
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
DC Electrical Characteristics Over the Operating Temperature and Supply Voltage Range (VCC = 3.3V 0.3V)
70V9089S Symbol |ILI| |ILO| VOL VOH Parameter Input Leakage Current(1) Output Leakage Current Output Low Voltage Output High Voltage Test Conditions VCC = 3.3V, VIN = 0V to VCC CE0 = VIH or CE1 = VIL, VOUT = 0V to VCC IOL = +4mA IOH = -4mA Min.
___
70V9089L Min.
___
Max. 10 10 0.4
___
Max. 5 5 0.4
___
Unit A A V V
3750 tbl 08
___
___
___
___
2.4
2.4
NOTE: 1. At Vcc < 2.0V input leakages are undefined.
DC Electrical Characteristics Over the Operating Temperature and Supply Voltage Range(6,7) (VCC = 3.3V 0.3V)
70V9089X9 Com'l Only Symbol ICC Parameter Dynamic Operating Current (Both Ports Active) Test Condition CEL and CER = VIL Outputs Disabled f = fMAX(1) Version COM'L IND COM'L IND CE"A" = VIL and CE"B" = VIH(3) Active Port Outputs Disabled, f=fMAX(1) Both Ports CER and CEL > VCC - 0.2V VIN > VCC - 0.2V or VIN < 0.2V, f = 0(2) CE"A" < 0.2V and CE"B" > VCC - 0.2V(5) VIN > VCC - 0.2V or VIN < 0.2V, Active Port Outp uts Disabled, f = fMAX(1) COM'L IND COM'L IND COM'L IND S L S L S L S L S L S L S L S L S L S L Typ.(4) 180 180
____ ____
70V9089X12 Com'l Only Typ.(4) 150 150
____ ____
70V9089X15 Com'l Only Typ.(4) 130 130
____ ____
Max. 260 225
____ ____
Max. 240 205
____ ____
Max. 220 185
____ ____
Unit mA
ISB1
Standby Current (Both Ports - TTL Level Inputs)
CEL and CER = VIH f = fMAX(1)
50 50
____ ____
75 65
____ ____
40 40
____ ____
65 50
____ ____
30 30
____ ____
55 35
____ ____
mA
ISB2
Standby Current (One Port - TTL Level Inputs)
110 110
____ ____
170 150
____ ____
100 100
____ ____
160 140
____ ____
90 90
____ ____
150 130
____ ____
mA
ISB3
Full Standby Current (Both Ports CMOS Level Inputs)
1.0 0.4
____ ____
5 3
____ ____
1.0 0.4
____ ____
5 3
____ ____
1.0 0.4
____ ____
5 3
____ ____
mA
ISB4
Full Standby Current (One Port CMOS Level Inputs)
100 100
____ ____
160 140
____ ____
90 90
____ ____
150 130
____ ____
80 80
____ ____
140 120
____ ____
mA
NOTES: 1. At f = fMAX, address and control lines (except Output Enable) are cycling at the maximum frequency clock cycle of 1/tCYC, using "AC TEST CONDITIONS" at input levels of GND to 3V. 2. f = 0 means no address, clock, or control lines change. Applies only to input at CMOS level standby. 3. Port "A" may be either left or right port. Port "B" is the opposite from port "A". 4. Vcc = 3.3V, TA = 25C for Typ, and are not production tested. ICC DC(f=0) = 90mA (Typ). 5. CEX = VIL means CE0X = VIL and CE1X = VIH CEX = VIH means CE0X = VIH or CE1X = VIL CEX < 0.2V means CE0X < 0.2V and CE1X > VCC - 0.2V CEX > VCC - 0.2V means CE0X > VCC - 0.2V or CE1X < 0.2V "X" represents "L" for left port or "R" for right port. 6. 'X' in part number indicates power rating (S or L). 7. Industrial temperature: for specific speeds, packages and powers contact your sales office.
3750 tbl 09
6.42 5
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
AC Test Conditions
Input Pulse Levels Input Rise/Fall Times Input Timing Reference Levels Output Reference Levels Output Load GND to 3.0V 3ns Max. 1.5V 1.5V Figures 1,2 and 3
3750 tbl 10
3.3V
3.3V
590 DATAOUT 435 30pF DATAOUT 435
590
5pF*
3750 drw 03
3750 drw 04
Figure 1. AC Output Test load.
Figure 2. Output Test Load (For tCKLZ, tCKHZ, tOLZ, and tOHZ). *Including scope and jig.
8 7 6 5 tCD1, tCD2 (Typical, ns) 4 3 2 1 0 -1
-10 pF is the I/O capacitance of this device, and 30pF is the AC Test Load Capacitance
20 40 60 80 100 120 140 160 180 200 Capacitance (pF)
3750 drw 05
,
Figure 3. Typical Output Derating (Lumped Capacitive Load).
6 6.42
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
AC Electrical Characteristics Over the Operating Temperature Range (Read and Write Cycle Timing)(3,4,5) (VCC = 3.3V 0.3, TA = 0C to +70C)
70V9089X9 Com'l Only Symbol tCYC1 tCYC2 tCH1 tCL1 tCH2 tCL2 tR tF tSA tHA tSC tHC tSW tHW tSD tHD tSAD tHAD tSCN tHCN tSRST tHRST tOE tOLZ tOHZ tCD1 tCD2 tDC tCKHZ tCKLZ Clock Cycle Time (Flow-Through) Clock Cycle Time (Pipelined)
(2) (2)
70V9089X12 Com'l Only Min. 30 20 12 12 8 8
____ ____
70V9089X15 Com'l Only Min. 35 25 12 12 10 10
____ ____
Parameter
(2)
Min. 25 15 12 12 6 6
____ ____
Max.
____ ____ ____ ____ ____ ____
Max.
____ ____ ____ ____ ____ ____
Max.
____ ____ ____ ____ ____ ____
Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns
Clock High Time (Flow-Through) Clock Low Time (Flow-Through) Clock High Time (Pipelined)
(2)
(2)
Clock Low Time (Pipelined)(2) Clock Rise Time Clock Fall Time Address Setup Time Address Hold Time Chip Enable Setup Time Chip Enable Hold Time R/W Setup Time R/W Hold Time Input Data Setup Time Input Data Hold Time ADS Setup Time ADS Hold Time CNTEN Setup Time CNTEN Hold Time CNTRST Setup Time CNTRST Hold Time Output Enable to Data Valid Output Enable to Output Low-Z(1) Output Enable to Output High-Z
(1) (2)
3 3
____ ____ ____ ____ ____ ____ ____ ____ ____
3 3
____ ____ ____ ____ ____ ____ ____ ____ ____
3 3
____ ____ ____ ____ ____ ____ ____ ____ ____
4 1 4 1 4 1 4 1 4 1 4 1 4 1
____
4 1 4 1 4 1 4 1 4 1 4 1 4 1
____
4 1 4 1 4 1 4 1 4 1 4 1 4 1
____
____ ____
____ ____
____ ____
____
____
____
____ ____
____ ____
____ ____
12
____
12
____
15
____
2 1
____ ____
2 1
____ ____
2 1
____ ____
7 20 9
____
7 25 12
____
7 30 15
____
Clock to Data Valid (Flow-Through) Clock to Data Valid (Pipelined)
(2)
Data Output Hold After Clock High Clock High to Output High-Z
(1)
2 2 2
2 2 2
2 2 2
9
____
9
____
9
____
Clock High to Output Low-Z(1)
Port-to-Port Delay tCWDD tCCS Write Port Clock High to Read Data Delay Clock-to-Clock Setup Time
____ ____
35 15
____ ____
40 15
____ ____
50 20
ns ns
3750 tbl 11
NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). This parameter is guaranteed by device characterization, but is not production tested. 2. The Pipelined output parameters (tCYC2, tCD2) apply to either or both left and right ports when FT/PIPE = VIH. Flow-through parameters (tCYC1, tCD1) apply when FT/PIPE = VIL for that port. 3. All input signals are synchronous with respect to the clock except for the asynchronous Output Enable (OE) and FT/PIPE. FT/PIPE should be treated as a DC signal, i.e. steady state during operation. 4. 'X' in part number indicates power rating (S or L). 5. Industrial temperature: for specific speeds, packages and powers contact your sales office.
6.42 7
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Timing Waveform of Read Cycle for Flow-Through Output (FT/PIPE"X" = VIL)(3,6)
tCYC1 tCH1 CLK CE0 tSC CE1 tHC tSC
(4)
tCL1
tHC
R/W
tSW tSA
tHW tHA An + 1 tCD1 tDC Qn tCKLZ
(1)
ADDRESS
(5)
An
An + 2
An + 3 tCKHZ (1)
DATAOUT
Qn + 1 tOHZ
(1)
Qn + 2 tOLZ
(1)
tDC
OE
(2)
tOE
3750 drw 06
Timing Waveform of Read Cycle for Pipelined Output (FT/PIPE"X" = VIH)(3,6)
tCYC2 tCH2 CLK CE0 tSC CE1 tHC tCL2
tSC
(4)
tHC
R/W
tSW tSA
tHW tHA An + 1 (1 Latency) tCD2 Qn tCKLZ
(1)
ADDRESS
(5)
An
An + 2 tDC Qn + 1
An + 3
DATAOUT
Qn + 2
(1)
tOHZ
tOLZ
(1)
OE
(2)
tOE
3750 drw 07 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. OE is asynchronously controlled; all other inputs are synchronous to the rising clock edge. 3. ADS = VIL, CNTEN and CNTRST = VIH. 4. The output is disabled (High-impedance state) by CE0 = VIH or CE1 = VIL following the next rising edge of clock. Refer to Truth Table 1. 5. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 6. "x" denotes Left or Right port. The diagram is with respect to that port.
8 6.42
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Timing Waveform of a Bank Select Pipelined Read(1,2)
tCH2 CLK tSA ADDRESS(B1) tSC CE0(B1) tCD2 DATAOUT(B1) tSA ADDRESS(B2) tHA A0 A1 A2 A3 A4 A5 A6 Q0 tDC tHA A0 tHC tSC tHC tCD2 tCKHZ Q1 tDC
(3)
tCYC2 tCL2
A1
A2
A3
A4
A5
A6
tCD2 Q3 tCKLZ
(3)
tCKHZ (3)
tSC CE0(B2) tSC tHC
tHC
tCD2 DATAOUT(B2) tCKLZ(3) Q2
tCKHZ(3)
tCD2 tCKLZ (3) Q4
3750 drw 08
Timing Waveform of a Bank Select Flow-Through Read(6)
tCH1 CLK tSA ADDRESS(B1) tSC tHA A0 tHC tSC tCD1 DATAOUT(B1) tSA ADDRESS(B2) tHA A0 A1 A2 A3 A4 A5 A6 D0 tDC tCD1 D1 tDC tCKLZ
(1)
tCYC1 tCL1
A1
A2
A3
A4
A5
A6
CE0(B1)
tHC tCKHZ
(1)
tCD1 D3 tCKHZ (1)
tCD1 D5 tCKLZ
(1)
tSC CE0(B2) tSC tHC
tHC
tCD1 DATAOUT(B2) tCKLZ
(1)
tCKHZ D2
(1)
tCD1 tCKLZ
(1)
tCKHZ D4
(1)
NOTES: 1. B1 Represents Bank #1; B2 Represents Bank #2. Each Bank consists of one IDT70V9089 for this waveform, and are setup for depth expansion in this example. ADDRESS(B1) = ADDRESS(B2) in this situation. 2. OE and ADS = VIL; CE1(B1), CE1(B2), R/W, CNTEN, and CNTRST = VIH. 3. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 4. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 5. OE = VIL for the Right Port, which is being read from. OE = VIH for the Left Port, which is being written to. 6. If tCCS < maximum specified, then data from right port READ is not valid until the maximum specified for tCWDD. If tCCS > maximum specified, then data from right port READ is not valid until tCCS + tCD1. tCWDD does not apply in this case.
3750 drw 08a
6.42 9
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Timing Waveform Port-to-Port Flow-Through Read(1,2,3,5)
CLK "A" tSW tHW R/W "A" tSA ADDRESS "A" tHA
NO MATCH
MATCH
tSD DATAIN "A"
tHD
VALID
tCCS (4) CLK "B" tCD1 R/W "B" tSW tHW tSA ADDRESS "B" tHA
NO MATCH
MATCH
tCWDD (4) DATAOUT "B" tDC
VALID
tCD1
VALID
tDC
3750 drw 09
NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 3. OE = VIL for the Port "B", which is being read from. OE = VIH for the Port "A", which is being written to. 4. If tCCS < maximum specified, then data from right port READ is not valid until the maximum specified for tCWDD. If tCCS > maximum specified, then data from right port READ is not valid until tCCS + tCD1. tCWDD does not apply in this case. 5. All timing is the same for both left and right ports. Port "A" may be either left or right port. Port "B" is the opposite of Port "A".
10 6.42
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Timing Waveform of Pipelined Read-to-Write-to-Read (OE = VIL)(3)
tCYC2 tCH2 tCL2 CLK
CE0 tSC tHC
CE1 tSW tHW R/W tSW tHW
ADDRESS
(4)
An tSA tHA
An +1
An + 2
An + 2 tSD tHD Dn + 2
An + 3
An + 4
DATAIN
(2)
tCD2 Qn READ
tCKHZ (1)
tCKLZ
(1)
tCD2 Qn + 3
DATAOUT
NOP
(5)
WRITE
READ
3750 drw 10
Timing Waveform of Pipelined Read-to-Write-to-Read (OE Controlled)(3)
tCH2 CLK CE0 tSC CE1 tSW tHW R/W tSW tHW tHC tCYC2 tCL2
ADDRESS(4)
An tSA tHA
An +1
An + 2 tSD tHD
An + 3
An + 4
An + 5
DATAIN
(2)
tCD2 Qn tOHZ
(1)
Dn + 2
Dn + 3
tCKLZ(1)
tCD2 Qn + 4
DATAOUT
OE READ WRITE READ
3750 drw 11
NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 3. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. "NOP" is "No Operation." Data in memory at the selected address may be corrupted and should be re-written to guarantee data integrity.
6.42 11
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Timing Waveform of Flow-Through Read-to-Write-to-Read (OE = VIL)(3)
tCH1 CLK tCYC1 tCL1
CE0 tSC CE1 tSW tHW R/W tSW tHW tHC
ADDRESS
(4)
An tSA tHA
An +1
An + 2
An + 2 tSD tHD
An + 3
An + 4
DATAIN
(2)
Dn + 2 tCD1 Qn tDC READ tCD1 Qn + 1 tCKHZ NOP
(5) (1)
tCD1 Qn + 3 tDC READ
tCD1
DATAOUT
tCKLZ WRITE
(1)
3750 drw 12
Timing Waveform of Flow-Through Read-to-Write-to-Read (OE Controlled)(3)
tCYC1 tCH1 tCL1 CLK CE0 tSC tHC
CE1 tSW tHW R/W tSW tHW
ADDRESS
(4)
An tSA tHA
An +1
An + 2 tSD tHD Dn + 2
An + 3
An + 4
An + 5
DATAIN
(2)
Dn + 3
tCD1 Qn
tDC
tOE tCD1
(1)
tCD1 Qn + 4 tDC
DATAOUT
tOHZ (1) OE READ WRITE
tCKLZ
READ
3750 drw 13
NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 3. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. "NOP" is "No Operation." Data in memory at the selected address may be corrupted and should be re-written to guarantee data integrity.
12 6.42
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Timing Waveform of Pipelined Read with Address Counter Advance (1)
tCH2 CLK tSA ADDRESS An tSAD tHAD ADS tSAD tHAD tHA tCYC2 tCL2
CNTEN tCD2 DATAOUT Qx - 1(2) Qx tDC READ EXTERNAL ADDRESS READ WITH COUNTER Qn
tSCN tHCN
Qn + 1
Qn + 2(2)
Qn + 3
COUNTER HOLD
READ WITH COUNTER
3750 drw 14
Timing Waveform of Flow-Through Counter Read with Address Counter Advance(1)
tCH1 CLK tSA ADDRESS tHA tCYC1 tCL1
An tSAD tHAD
ADS
tSAD tHAD tSCN tHCN
CNTEN tCD1 DATAOUT Qx(2) tDC READ EXTERNAL ADDRESS READ WITH COUNTER COUNTER HOLD READ WITH COUNTER
3750 drw 15
Qn
Qn + 1
Qn + 2
Qn + 3(2)
Qn + 4
NOTES: 1. CE0 and OE = VIL; CE1, R/W, and CNTRST = VIH. 2. If there is no address change via ADS = VIL (loading a new address) or CNTEN = VIL (advancing the address), i.e. ADS = VIH and CNTEN = VIH, then the data output remains constant for subsequent clocks.
6.42 13
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Timing Waveform of Write with Address Counter Advance (Flow-Through or Pipelined Outputs) (1)
tCH2 CLK tSA ADDRESS tHA tCYC2 tCL2
An
INTERNAL(3) ADDRESS tSAD tHAD ADS
An(7)
An + 1
An + 2
An + 3
An + 4
CNTEN tSD tHD DATAIN Dn WRITE EXTERNAL ADDRESS Dn + 1 Dn + 1 Dn + 2 Dn + 3 Dn + 4
WRITE WRITE WITH COUNTER COUNTER HOLD
WRITE WITH COUNTER
3750 drw 16
Timing Waveform of Counter Reset (Pipelined Outputs)(2)
tCH2 CLK tSA tHA
(4)
tCYC2 tCL2
ADDRESS INTERNAL(3) ADDRESS R/W ADS CNTEN tSCN tHCN tSRST tHRST CNTRST DATAIN
(5)
An Ax (6) tSW tHW
An + 1
An + 2
0
1
An
An + 1
tSAD tHAD
tSD
tHD D0 Q0 Q1 READ ADDRESS n READ ADDRESS n+1 Qn
DATAOUT COUNTER RESET
(6)
WRITE ADDRESS 0
READ ADDRESS 0
READ ADDRESS 1
NOTES: 3750 drw 17 1. CE0 and R/W = VIL; CE1 and CNTRST = VIH. 2. CE0 = VIL; CE1 = VIH. 3. The "Internal Address" is equal to the "External Address" when ADS = VIL and equals the counter output when ADS = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 6. No dead cycle exists during counter reset. A READ or WRITE cycle may be coincidental with the counter reset.ADDR0 will be accessed. Extra cycles are shown here simply for clarification. 7. CNTEN = VIL advances Internal Address from `An' to `An +1'. The transition shown indicates the time required for the counter to advance. The `An +1' address is written to during this cycle.
14 6.42
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Functional Description
The IDT70V9089 provides a true synchronous Dual-Port Static RAM interface. Registered inputs provide minimal set-up and hold times on address, data, and all critical control inputs. All internal registers are clocked on the rising edge of the clock signal, however, the self-timed internal write pulse is independent of the LOW to HIGH transition of the clock signal. An asynchronous output enable is provided to ease asynchronous bus interfacing. Counter enable inputs are also provided to stall the operation of the counter registers for fast interleaved memory applications. A HIGH on CE0 or a LOW on CE1 for one clock cycle will power down the internal circuitry to reduce static power consumption. Multiple chip enables allow easier banking of multiple IDT70V9089's for depth expansion configurations. When the Pipelined output mode is enabled, two cycles are required with CE0 LOW and CE1 HIGH to re-activate the outputs.
Depth and Width Expansion
The IDT70V9089 features dual chip enables (refer to Truth Table I) in order to facilitate rapid and simple depth expansion with no requirements for external logic. Figure 4 illustrates how to control the various chip enables in order to expand two devices in depth. The IDT70V9089 can also be used in applications requiring expanded width, as indicated in Figure 4. Since the banks are allocated at the discretion of the user, the external controller can be set up to drive the input signals for the varioius devices as required to allow for 16-bit or wider applications.
A16
IDT70V9089
CE0 CE1 VCC
IDT70V9089
CE0 CE1 VCC
Control Inputs
Control Inputs
IDT70V9089
CE1 CE0
IDT70V9089
CE1 CE0 CNTRST CLK ADS CNTEN R/W OE
Control Inputs
Control Inputs
3750 drw 18
Figure 4. Depth and Width Expansion with IDT70V9089
6.42 15
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Ordering Information
IDT XXXXX Device Type A Power 99 Speed A Package A Process/ Temperature Range
Blank I(1)
Commercial (0C to +70C) Industrial (-40C to +85C)
PF
100-pin TQFP (PN100-1)
9 12 15 S L
Commercial Only Commercial Only Commercial Only Standard Power Low Power
Speed in nanoseconds
70V9089 512K (64K x 8-Bit) Synchronous Dual-Port RAM
3750 drw 19
NOTE: 1. Industrial temperature range is available. For specific speeds, packages and powers contact your sales office.
Ordering Information for Flow-through Devices
Old Flow-through Part 70V908S/L25 70V908S/L30 New Combined Part 70V9089S/L12 70V9089S/L15
3750 tbl 12
16 6.42
IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM
Industrial and Commercial Temperature Ranges
Datasheet Document History
1/18/99: Initiated datasheet document history Converted to new format Cosmetic and typographical corrections Added additional notes to pin configurations Page 14 Added Depth and Width Expansion section. Page 3 Deleted note 6 for Table II Replaced IDT logo Combined Pipelined 70V9089 family and Flow-through 70V908 family offerings into one data sheet Changed 200mV in waveform notes to 0mV Added corresponding part chart with ordering information Page 3 Changed information in Truth Table II Page 4 Increased storage temperature parameters Clarified TA parameter Page 5 DC Electrical parameters-changed wording from "open" to "disabled" Removed Preliminary Status
6/11/99: 11/12/99: 3/31/00:
1/10/01:
CORPORATE HEADQUARTERS 2975 Stender Way Santa Clara, CA 95054
for SALES: 800-345-7015 or 408-727-6116 fax: 408-492-8674 www.idt.com
for Tech Support: 831-754-4613 DualPortHelp@idt.com
The IDT logo is a registered trademark of Integrated Device Technology, Inc.
6.42 17


▲Up To Search▲   

 
Price & Availability of 70V9089DS82476

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X